Jinho Kim 1 Article
Delayed Obstruction of Endotracheal Tube by Previously Aspirated Foreign Body: A Case Report
Sungsik Chon, Jinho Kim, Shin Ok Koh, Jung Goo Cho, In Soon Hwang, In Seon Jin
Korean J Crit Care Med. 2005;20(2):174-177.
  • 1,506 View
  • 26 Download
AbstractAbstract PDF
Acute airway obstruction during endotracheal intubation status is embarrassing and critical situation which requires early diagnosis and immediate management. Endotracheal tube obstruction with foreign body is rare but a variety of objects have been reported. We present a case of endotracheal tube obstruction as a result of previous aspirated foreign body that moved from the bronchial tree into the endobroncheal tube.